POTAIN · LUFFING JIB
POTAIN MRH 125
Hydraulic luffing jib on a topless upper. VVH rams, no luffing rope. Built for tight urban sites. Lift to the serial chart in the cab.
- DOCUMENT
- GOSPEL-CRN-002
- REVISION
- 01 CURRENT
- EFFECTIVE
- 2026-09-01
- OWNER
- GOSPEL Safety
- APPROVED BY
- GOSPEL
- REVIEW
- 2027-09-01
Lift to the serial chart in the cab — this jib, this reeving, this mast, this ballast. The files below are Manitowoc published range sheets. Operator, maintenance and lubrication manuals for this serial live in the cab and on Manitowoc Crane Care.
PUBLISHED RANGE
Capacity
8 t (8.8 USt) max. 50 m (164 ft) jib. 2 t (2.2 USt) at 50 m. Jib in 5 m steps from 30 m to 50 m.
Footprint
Counter-jib 7 m. Weathervane radius about 10 m on the 50 m jib. Cab can sit left or right of the jib.
Luffing
VVH hydraulic. Jib can be fully raised in about two minutes. Oil tank and retention tank with level gauges. 2-fall / 4-fall reeving.
Mast
K-mast 1.6 m and 2.0 m. Cab-IN where fitted. Upper transports as a short package — four containers or four trucks for the 50 m jib upper.
LOAD CHARTS + DATA SHEETS
Imperial. 02D_ASCEUSt_MRH125.
MRH 125 — EN 14439 C25 DATA SHEET →
Metric load curves, ballast, mechanisms.
MANUALS + MAINTENANCE
MANITOWOC MANUALS — BRAND POTAIN →
Operator, service, inspection and lubrication for this serial. Hydraulic luffing lives in the maintenance manual — follow that interval.
INSPECT
- Serial, jib length, reeving, counterweight and mast match the chart in the cab
- Hydraulic luffing: rams, hoses, tank, retention tank, leaks, level
- Jib pins, keepers, luffing geometry. Jib can go near-vertical — check clearance
- Hoist rope, hook block, anti-two-block
- Slew, weathervaning at the published short radius for this jib
- Mast bolts, pins, ties. Cab side (left or right) as installed
- Limit devices and overload. Anemometer
- Out-of-service jib position per the OEM for this wind
MAINTAIN
- Hydraulic oil, filters, ram glands, hoses — OEM interval
- Luffing pins and greasing
- Hoist winch oil, brakes, rope
- Slew grease and bolts
- Electrical and earthing
- CCS or cab maintenance screen where fitted
GOSPEL FORMS
LUFFING JIB INSPECTION — GOSPEL-FRM-028 →
TOWER PRE-USE — GOSPEL-FRM-027 →
PROVENsin(). Current version on this site.