Outriggers

ProvisionalLevel 1Level 3Red Seal

REDMC sample · development — OEM chart configuration; WorkSafeBC Part 14

A mobile crane’s outriggers must be fully extended and set unless which condition is true?

Explanation

The manufacturer’s load chart in use lists that outrigger configuration. — Capacity is only valid for the configuration on the chart in the cab — including outrigger spread.

Why the others are wrong

The operator prefers a shorter footprint on a tight site. — Preference is not a chart condition. Short-rigging without the matching chart is overloading the machine.

The ground looks firm and the lift is under 50% of chart. — Neither ‘looks firm’ nor an arbitrary percentage replaces the published configuration.

A supervisor has signed a deviation in the FLHA. — A site form cannot raise a crane’s rated capacity or change the OEM configuration rules.

Source. REDMC sample · development — OEM chart configuration; WorkSafeBC Part 14